Subscribe to our Newsletter
Model No: ES350-F0-0K4G/0K7P-1B
Cumark Industrial VFD Converter Variable Frequency Drive AC Inverter 380V for Pump Fan Conveyor
Cumark ES350 Series is a high-performance general purpose frequency inverter designed for reliable and efficient motor speed control.
It supports SVC vector control, suitable for both asynchronous motors and permanent magnet synchronous motors (PMSM).
Power range: 0.4kW – 4kW
Voltage:
Single Phase 220V
Three Phase 220V
Three Phase 380V
Widely used in packaging machines, conveyors, fans, pumps, CNC equipment, textile machines and general industrial automation.
It supports SVC vector control, suitable for both asynchronous motors and permanent magnet synchronous motors (PMSM).
Power range: 0.4kW – 4kW
Voltage:
Single Phase 220V
Three Phase 220V
Three Phase 380V
Widely used in packaging machines, conveyors, fans, pumps, CNC equipment, textile machines and general industrial automation.
Delivery :
FOB
minimum order :
1 piece
Supply Ability :
10piece / Day
Country of Origin :
China
Quantity :
US $69.00 - US $72.00 / piece
Frequency inverter,ac drive,Frequency converter,solar pump inverter,variable frequency drive
Item | Specification and Technical Data |
Input voltage U1 | 220V/380V/500/690V+15%;signal/three-phase power |
Input frequency f1 | 50...60Hz+5Hz |
Output voltage U2 | 0..U1 (V)(The maximum output voltage equals the input power voltage.) |
Output frequency f2 | 0-599Hz |
Carier frequency | 2-8 KHz (The device can intelligently and automatically make optimal adjustmentaccording to load characteristics and drive temperature.) |
Input voltageunbalance degree | Maximum: +3% of rated inter-phase input voltage |
Efficiency | ≈98% (when operating at rated power) |
Speed range | 0-599Hz(0~30000 rpm,60000rpm is optional ) |
Resolution of given speed | Digital setting:1RPM Analog setting: 0.025% of maximum RPM |
Control mode | Open-loop vector control/close-loop vector control |
Starting speed | 200%@ 0.25Hz@ SVC control 200% @0Hz@ FVC control |
Speed ratio | 1:200@ SVC control 1:3000@ FVC control |
Overload capacity | Heay load application: 60s at 150% rated current @40°C. The time depends on the drive temperature under other conditions. General application: 60s at 120% rated curent @40°C. The time depends on the drive temperature under other conditions. |
Torque boost | Automatic torque boost. Manual torque boost 0.1%-30% |
Built-in PID | Conveniently achieve the process control close-loop control system |
Torque limiting and control | The torque is automatically limited operating (to avoid frequent overcurrent jumping fault due totoo large torque). |
Protection function | Output shortcircuit protection, input & output phase loss protection, overcurrent protection, overvoltage protection,undervoltage protection, overheat protection, overload protection, brake chopper overload protection, brake chopper shortcircuit protection, brake resistor overload protection |
Bus communication | The standard configuration uses the built-in Modbus/communication, which can beextended to Profibus-DP, CANopen bus communication. Etc. |
Command input mode | Control keyboard input, control terminal input bus communication input which can beswitched mutually. |
Speed reference mode | Digital giving, analog voltage (current) giving, pulse giving, bus communication giving and PID giving, which are mutually switched. |
Input terminal (input) | The followings are included in standard configuration :6 (FO) /7 (F1 and above) digital input terminals, where,DI6 (FO) DI7 (F1 and above)supports the maximum of 50 kHz high-speed pulse input.2 (F0) /3 (F1 and above) analog input terminals (where, at least 2 supports 0-10V voltageinput or 0-20 mA or 4-20mA voltage input)The followings are extended as cards :5 digital input terminals2 analog input terminals, supporting input of -10V to+10V voltage (Optional) |
Output terminal (output) | The followings are included in standard configuration:1 high-speed pulse output terminal (supporting 0-50 kHZ square signal output )1 (FO) /2 (F1 and above) digital output terminals1 (F0) 12 (F1 and above) relay output terminals1 (F0) 12 (F1 and above) analog output terminals (supporting0-10V voltage outputor 0-20mA or 4-20 mA voltage output) |
Protection grade | IP20 (UL-open type), (the medium cavity with air vents on two sides for some F0** models)Electrical cavity full closed design for small- and medium-power models, Top/Left and rightsides can reach IP40 |